Page view 1
Specifications
Dimensions
SAMPI spa
A unit of IDEX Corporation
Via Amerigo Vespucci, 1
55011 Altopascio (Lucca) – Italy
Phone: +39 0583 24751
Fax: +39 0583 264748
www.sampi.it
Voltage (V+): +8 to +24 Vdc (POD5 is +5 Vdc) ±5%
Current Supply 26 mA typical
Output Signal Resolution 100 pulses per encoder revolution, unscaled
Square Wave Single or dual quadrature channel output
Pulse Timing Nominal 50% on and 50% off
Operating Temperature Range -40°C to 85°C (-40°F to 185°F)
Output
Current sinking 100 mA maximum in “ON”
state; V+ supply @ 1.0 KΩ in “OFF” state
Optional Open Drain FET (Field Effect Transistor).
FET Rating (Drain to Source Voltage)
+30 Vdc maximum
Electromagnetic Compatibility To IEC 801 standard